◆ Advanced DSP digital control to make the control system more stable and reliable
◆ Double transform on-line design, adopting power factor coorrection (PFC) technology, input power factor is up to 0.9
◆ Output power factor is 0.9(0.8 is available optional),with higher actual load capacity to save users’ investiment
◆ intelligent charging management, ±16 ~ ±20pcs(32-40pcs) batteries to select
◆ Plentiful options, USB or RS485 communication interface, SNMP card (optional), parallel board (optional)
◆ ECO working mode, high efficiency and energy saving reduce users’ cost
◆ Parallel redundancy function, it enables to connect 4 units in parallel, and the battery pack can be shared in parallel
◆ Four modes (three phase , three-single phase, single-three phase, single phase)
FEATURES
◆ Advanced DSP digital control to make the control system more stable and reliable
◆ Double transform on-line design, adopting power factor coorrection (PFC) technology, input power factor is up to 0.9
◆ Output power factor is 0.9(0.8 is available optional),with higher actual load capacity to save users’ investiment
◆ intelligent charging management, ±16 ~ ±20pcs(32-40pcs) batteries to select
◆ Plentiful options, USB or RS485 communication interface, SNMP card (optional), parallel board (optional)
◆ ECO working mode, high efficiency and energy saving reduce users’ cost
◆ Parallel redundancy function, it enables to connect 4 units in parallel, and the battery pack can be shared in parallel
◆ Four modes (three phase , three-single phase, single-three phase, single phase)
Model | TSA33 60KX | TSA33 80KX | |
Rated Power | 60kVA/54kW | 80kVA/72kW | |
INPUT | Voltage Range | 208-478Vac 3P4W+G | |
Working Frequency Range | 45-55Hz at 50Hz/ 54-66Hz at 60Hz (self-adapting) | ||
Input Power Factor | ≥0.99 | ||
OUTPUT | Rated Voltage and Accuracy | 380/400/415Vac(1±1%) 3P4W+G | |
Output Frequency | Synchronized with input ; mains frequency ≥ maximum ± 10%, output frequency is 50 (± 0.2%)Hz ; 50/60 ± 0.2% (battery) | ||
Rated Current | 91A | 121A | |
Output Power Factor | 0.9 | ||
Output Harmonic Wave | ≤2% liner ; ≤5% non-liner | ||
Crest Factor | 3 : 1 | ||
Output Overload | Load≤110%: 60 mins;Load≤125%: 10 mins;Load≤150%: 1 min; Load≥150% shutdown immediately | ||
Transfer Time | 0 ms (Normal mode ← → Battery Mode) | ||
Efficiency | normal mode ≥ 94.5% | ||
BATTERY | Rated Voltage | default ± 192Vdc | |
Quantity | 32~40 | ||
Charging Current | 20A (Max.) | ||
Dimension (LxWxH) mm | 865*300*960 | ||
Weight | 85.5kg | ||
Working Temperature | 0℃〜40℃ | ||
Altitude | <1500m | ||
Storage | -25~55℃ | ||
Relative Humidity | 0-95% (non-condensing) | ||
* Product specifications are subject to change without further notice. |