RM Series 50-600KVA Modular UPS

◆ N+X parallel redundancy design, and the system availability up to 99.999%
◆ Using hot-swap technology, modules can be added online and pulled out online to achieve ”zero” maintenance time
◆ The LCD touch screen of the cabinet provides rich UPS status information
◆ Using advanced three-level technology and digital control, the system is stable and reliable, and the efficiency of the whole machine is up to 96%
◆ High power density design, output can be connected to completely unbalanced loads.
◆ Intelligent design, battery capacity and charging current can be set through the LCD panel.
◆ The number of batteries is optional, and the battery pack can be shared in parallel mode.
◆ Strong load adaptability for linear and nonlinear load.

Product Categories

CHARACTERISTICS & SPECIFICATIONS

FEATURE

◆ High Reliability
N+X parallel redundancy design, and the system availability up to 99.999%. MTBF lasts more than 250,000 hours to meet the high reliability demand of the power supply system for critical loads. Flexible parallel redundancy setting enable the system to provide maximum output capacity.

Parallel redundancy of control system: The control mode is divided into decentralized control and centralized management. The centralized control unit is connected in parallel for redundancy, and a fault does not affect the operation of the whole machine. Optimised distribution and combining cabinets ensure the safety of parallel systems.

The centralized monitoring module is hot-swappable. After removing the monitoring module, the system can work normally. The use of centralized bypass power supply can improve the power supply capacity.

EPO function: Press the EPO button urgently to shut down in an emergency; the EPO button is designed for protection and avoid misoperation; it has a remote emergency shutdown (REPO) function.

◆ Convenient and Fexible
Modular design, consisting of 1~12 modules in parallel, with a maximum power of 600kW, users can gradually increase the number of modules; using hot-swap technology, modules can be added online and pulled out online to achieve “zero’ maintenance time.

Maintenance downtime is short. When the number off aulty modules is less than the number of redundant modules, the downtime is zero. But if the number of faulty modules is more than the number of redundant UPS modules, the maintenance time will not exceed 5 minutes.

The LCD touch screen of the cabinet provides rich UPS status information, warning information, fault information, etc. With single-module LCD, users can better understand the working status of the module through the module LCD light. In an emergency, the UPS can be switched to the maintenance bypass for power supply, and maintenance personnel can perform online maintenance safely.

◆ Advanced Technology
The structure of each part adopts digital control, with excellent performance, high system stability, self-protection and fault diagnosis capabilities, avoiding the risk of operating device failure, and making the control system more stable and reliable.

Using advanced three-level technology, the efficiency of the whole machine is as high as 96%.

High power density design, 50kW single module, size (WxDxH) 440x620x130mm. The output can be connected to a completely unbalanced load. When the output is connected to an unbalanced load, the input current is three-phase balanced, which can balance the load of the three-phase grid.

◆ Intelligent Design
The charging current can be set, and the user-configured battery capacity and charging current can be set through the panel LCD; automatic and smooth switching between constant voltage charging mode, constant current charging mode and floating charging mode is realized.

The intelligent charging mode adopts an advanced two-stage three-stage charging method, which can well take into account the goals of fast charging and prolonging battery life, saving users’ battery investment.

Provide a wealth of optional accessories, users can choose to install optional accessories such as isolation transformer, power distribution board, SNMP card, relay dry contact card, etc. to form a small and medium power distribution system.

◆ Green and Environmental Protection
The standard cabinet is adopted, which perfectly matches the application environment of the computer room and saves the area. Parallel machine with battery sharing greatly reduces the number of battery configurations,and users can configure batteries according to backup time. The number of optional external battery,the users can choose accorrdingly (30/32/34/36/38/40/42/44/46/48/50(30-50pcs optional)

 

MODEL RM50 300 RM50 400 RM50 500 RM50 600
Capacity UPS Cabinet 50-300kVA 50-400KW 50-500KW 50-600KW
Power Module 50KW
Max Quantity of Module 6 8 10 12
Input Main
Input
Rated Input Voltage 380/400/415Vac
Input Voltage Range 138~485Vac
Wiring 3P4W+G
Frequency Range 40~70Hz
Input Power Factor ≥0.99
Input Current Harmonic Wave ≤3% (100% non-linear)
Bypass
Input
Rated Input Voltage 380/400/415Vac
Input Voltage Range 220 upper limit: 25% (optional +10%、+15%、+20% )     /     230 upper limit: 20% (optional +10%、+15% )
240 upper limit: 15% (optional +10%)     /     Lower limit: -45% (optional -20%、-30%)
Wiring 3P4W+G
Bypass synchronization tracing range(Hz) ± 10%
Generator Support
Power Walking In Support
Bypass Flow Backward Support
Output Voltage 380/400/415Vac ± 1%
Power Factor 1
Frequency Mains Mode : ±1% / ±2% / ±4% / ±5% / ±10% Settable ; Battery Mode : (50/60 ± 1%) Hz
Waveform Sine Wave
Crrst Factor 3 : 1
Input Current Harmonic Wave ≤ 2% (100% linear load) ; ≤ 3% (100% non-linear load)
Conversion Time 0ms
Efficiency 96%
Overload Capacity 110% load: convert to bypass after 60 mins; 125% load: convert to bypass after 10 mins; 150% load: convert to bypass after 1 min
Battery Maximum charging current of module 20
Battery Voltage 30-50 pcs optional, default 36 pcs; Optional voltage: ±180Vdc/±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc/
±252Vdc/±264Vdc/±276Vdc/±288Vdc/±300Vdc; (30/32/34/36/38/40/42/44/46/48/50 pcs of battery)
Environment Operating Temperature 0~40℃
Storage Temperature -25 ~ 55℃ ( excluded battery)
Humidity Range 0-95% (non-condensing)
Altitude <1500m (derating if exceeding 1500m)
Noise (1 meter distance) <68dB <70dB
Other
Functions
Protection Function Short circuit; overload; over temperature; output overvoltage or undervoltage;
battery undervoltage; fan fault alarm; bypass flow backward; anti-thunder
Alarm Function Mains abnormal; Overload; UPS fault; Battery undervoltage and other alarms
Communication Function CAN; RS485; Network Port; Dry contact Port; Parallel Port; LBS Port; Intelligent Slot; Temperature Sensor Port
Physical
Characteristic
Dimension (LxWxH) mm Cabinet 600*850*2000 1200*850*2000 1200*850*2000
Module 440*620*130
Weight (Net Weight) kg Cabinet 260 280/600 645 720
Module 36
Operative Standard YD/T 2165-2010
* Product specifications are subject to change without further notice.